Publications
List of our Publications
Our online database since 1996
Reprints are available on request (paper copies are available free of charge and for personal use only).
(last update February 24, 2021)
2021
- S. Cattini, D. Cassanelli, L. D. Cecilia, L. Ferrari and L. Rovati, A Procedure for the Characterization and Comparison of 3-D LiDAR Systems, in IEEE Transactions on Instrumentation and Measurement, vol. 70, pp. 1-10, 2021, Art no. 7002110, doi: 10.1109/TIM.2020.3043114.
- S. Cattini and L. Rovati, A Review on Guided Optical Feedback in Super-Luminescence Diodes for Metrological Purposes, in Journal of Lightwave Technology, doi: 10.1109/JLT.2020.3035565.
- S Cattini, S Truzzi, L Accorsi, L Rovati, A measuring instrument for in-line and real-time measurement of blood-pCO2 in extracorporeal-circulation, IEEE Transactions on Instrumentation and Measurement, vol. 70, pp. 1-9, 2021, Art no. 4000809, DOI: 10.1109/TIM.2020.3017030
2020
- S Cattini, S Truzzi, L Accorsi, L Rovati, Performances and robustness of a fluorescent sensor for nearly-neutral pH measurements in healthcare, IEEE Transactions on Instrumentation and Measurement, vol. 69, no. 10, pp. 7658-7665, DOI:10.1109/TIM.2020.2984964
- S Cattini, L Di Cecilia, L Ferrari, L Rovati, Optical characterization of the beams generated by 3D-LiDARs: proposed procedure and preliminary results on MRS1000, IEEE Transactions on Instrumentation and Measurement, vol. 69, no. 10, pp. 7796-7804, DOI:10.1109/TIM.2020.2984137
- S Cattini, L Accorsi, S Truzzi, L Rovati, On the development of an instrument for in-line and real-time monitoring of blood-pH in extracorporeal-circulation, IEEE Transactions on Instrumentation and Measurement, Volume: 69, Issue: 8, DOI: 10.1109/TIM.2019.2961499
- L Rovati, L Di Cecilia, S Cattini, On the feasibility of Absolute Distance Measurement by using Optical-Feedback into a Superluminescent Diode Cavity, IEEE Transactions on Instrumentation and Measurement, Volume: 69, Issue: 5, DOI: 10.1109/TIM.2019.2956421
- S Cattini, L Rovati, L Di Cecilia and, L Ferrari, Comparison of the VLP-16 LiDAR system with an absolute interferometer, 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), DOI: 10.1109/I2MTC43012.2020.9128651
2019
- L Rovati, L di Cecilia, S Cattini, Optical Feedback into a Superluminescent Diode Cavity for Absolute Distance Measurements, 2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), DOI: 10.1109/I2MTC.2019.8826828
2018
- L Rovati, S Cattini, P Fabbri, L Ferrari, Fluorescence pH Sensor Based on Polymer Film, 2018 International Flexible Electronics Technology Conference (IFETC), 1-5, 2018
- G Masetti, F Marazzi, L Di Cecilia, L Rovati, IOT-Based Measurement System for Wine Industry, 2018 Workshop on Metrology for Industry 4.0 and IoT, 163-168, 2018
- L Di Cecilia, F Marazzi, L Rovati, Spectral repeatability of a hyperspectral system for human iris imaging, 2018 IEEE 4th International Forum on Research and Technology for Society and Industry
2017
- L Ferrari, L Rovati, MP Costi, R Luciani, A Venturelli, S Cattini, Feasibility Study on a Measurement Method and a Portable Measuring System to Estimate the Concentration of Cloxacillin and β-Lactamase in Milk, Journal of Sensors, https://doi.org/10.1155/2017/5742359, 2017
- L Di Cecilia, S Cattini, F Giovanardi, L Rovati, Single-arm self-mixing superluminescent diode interferometer for flow measurements, Journal of Lightwave Technology 35 (16), 3577-3583, 2017
- L Ferrari, L Rovati, MP Costi, A Venturelli, R Luciani, S Cattini, On the feasibility of a CENTA-based biosensor to measure antibiotics concentration in milk, European Conference on Biomedical Optics, 1041302, 2017
- L Di Cecilia, F Marazzi, L Rovati, A hyperspectral imaging system for the evaluation of the human iris spectral reflectance, Ophthalmic Technologies XXVII 10045, 100451S, 2017
- L Di Cecilia, L Rovati, S Cattini, An improved optical scheme for self-mixing low-coherence flowmeters, Optical Diagnostics and Sensing XVII: Toward Point-of-Care, 2017 Diagnostics 10072
- L Peretto, R Tinarelli, L Rovati, M Bernabei, On the behavior of LED lamps under non-sinusoidal voltage conditions, 2017 IEEE International Instrumentation and Measurement Technology, 2017
- L Di Cecilia, F Marazzi, L Rovati, Hyperspectral imaging of the human iris, European Conference on Biomedical Optics, 104120R, 2017
- N Lenzini, L Rovati, L Ferrari, Effects of the density and homogeneity in NIRS crop moisture estimation, Optical Measurement Systems for Industrial Inspection X 10329, 103294O, 2017
- L Di Cecilia, F Marazzi, L Rovati, An improved imaging system for hyperspectral analysis of the human iris, 2017 IEEE 3rd International Forum on Research and Technologies for Society, 2017
2016
- O Priolisi, A Fabrizi, G Deon, F Bonollo and, S Cattini (2016). Morphology evolution of gold nanoparticles as function of time, temperature and Au(III)/sodium ascorbate molar ratio, Journal of Nanoparticle Research, Vol 18(1), pp. 1-13, doi: 10.1007/s11051-015-3308-7
- F Crespi, S Cattini, M Donini, A Bandera, L Rovati (2016). In vivo real time non invasive monitoring of brain penetration of chemicals with near-infrared spectroscopy: concomitant PK/PD analysis, Journal of Neuroscience Methods, Vol 258, pp.79-86, doi:10.1016/j.jneumeth.2015.10.011
- S Cattini, F Bondioli, Light-storing photocatalyst: the possibility of activating titanium dioxide by photoluminescence, Journal of applied biomaterials & functional materials 14 (4), 477-482, 2016
- S Cattini, L Rovati, A simple calibration method to quantify the effects of head movements on vision-based eye-tracking systems, 2016 IEEE International Instrumentation and Measurement Technology, 2016
- L Rovati, S Cattini, F Crespi, Near-infrared spectroscopy for non-invasive monitoring of drugs blood-brain barrier penetration, 2016 IEEE International Instrumentation and Measurement Technology, 2016
- S Cattini, L Rovati, Measuring haemolysis in haemodialysis: Comparison between a new and existing data processing algorithms, 2016 IEEE International Instrumentation and Measurement Technology, 2016
2015
- S. Cattini, L. Rovati (2015). Design and performance of an Hb measuring system: Viability of its use in a haemodialysis, Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International, pp. 1147 – 1152, doi: 10.1109/I2MTC.2015.7151433 [PDF]
- S. Cattini, L. Rovati (2015). A simple measuring system and calibration method to investigate light transmission ability of light-transmitting fiber posts, Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International, pp. 1141 – 1146, doi: 10.1109/I2MTC.2015.7151432 [PDF]
- G Verzellesi, M Bernabei, L Rovati, M Mandurrino, F Bertazzi, M Goano, M Meneghini, G Meneghesso, and E Zanoni (2015). (Invited) Efficiency droop in Gallium Nitride based light-emitting diodes: physical mechanisms and technological remedies, THE EMN GUANGZHOU MEETING 2015, Springer, pp. 47-48 [PDF]
- S. Cattini, L. Rovati (2015). An Optical Technique for Real-Time Monitoring of Hemolysis During Hemodialysis, Instrumentation and Measurement, IEEE Transactions on, Volume:PP, Issue: 99, pp. 1-10, doi: 10.1109/TIM.2015.2490939 [PDF]
- M. Mandurrino , M. Goano , S. Dominici , M. Vallone , F. Bertazzi , G. Ghione , M. Bernabei , L. Rovati , G. Verzellesi , M. Meneghini , G. Meneghesso , E. Zanoni (2015) , Trap-assisted tunneling contributions to subthreshold forward current in InGaN/GaN light-emitting diodes, Proc. SPIE 9571, Fourteenth International Conference on Solid State Lighting and LED-based Illumination Systems, 95710U, doi:10.1117/12.2187443
- M. Bernabei, L. Rovati, L. Peretto, R. Tinarelli (2015). Measurement of the pupil responses induced by RGB flickering stimuli, Instrumentation and Measurement Technology Conference (I2MTC), 2015 IEEE International, pp. 1634 – 1639, doi: 10.1109/I2MTC.2015.7151524
2014
- U. Carletti, S. Cattini, R. Lodi, A. Petralia, L. Rovati, D. Zaffe (2014). An in vitro model of a system of electrical potential compensation in extracorporeal circulation, JOURNAL OF ARTIFICIAL ORGANS, in press, doi:10.5301/ijao.5000286
- S. Cattini and L. Rovati (2014). A simple and robust optical scheme for self-mixing low-coherence flowmeters, Proc. SPIE 8951, Optical Diagnostics and Sensing XIV: Toward Point-of-Care Diagnostics, 895102, doi:10.1117/12.2035962 [PDF]
- M. Bernabei, R. Tinarelli, L. Peretto and, L. Rovati (2014). A simple handheld pupillometer for chromatic Flicker studies, Proc. SPIE 8930, Ophthalmic Technologies XXIV, 89300E, doi:10.1117/12.2038443
- L. Ferrari, L. Rovati, P. Fabbri, F. Pilati (2014). On-line pH Measurements of Near-Neutral Solutions by a Disposable Polymer Based Probe, Sensors Lecture Notes in Electrical Engineering, Vol. 162, pp 405-409, doi: 10.1007/978-1-4614-3860-1_72
- S. Cattini, L. Rovati, D. Cianciavicchia, P. Monari, A. Sicuri, and M. Bernabei (2014). A simple measuring system for early detection of haemolysis during haemodialysis, Instrumentation and Measurement Technology Conference (I2MTC), 2014 IEEE International, pp. 282–287, doi: 10.1109/I2MTC.2014.6860753 [PDF]
- M. Bernabei, R. Tinarelli, L. Peretto, L. Rovati (2014). A simple portable polychromatic pupillometer for human eye annoyiance measurement, Instrumentation and Measurement Technology Conference (I2MTC), 2014 IEEE International, pp. 1207-1211, doi: 10.1109/I2MTC.2014.6860935
2013
- L. Ferrari, L. Rovati, P. Fabbri and F. Pilati (2013). Continuous haematic pH monitoring in extracorporeal circulation using a disposable florescence sensing element, J. Biomed. Opt. Vol. 18(2), pp. 027002, doi:10.1117/1.JBO.18.2.027002. [PDF]
- C. Zanardi, L. Ferrari, B. Zanfrognini, L. Pigani, F. Terzi, S. Cattini, L. Rovati and R. Seeber (2013). Development of a Sensor System for the Determination of Sanitary Quality of Grapes, Sensors, Vol. 13(4), pp. 4571-4580; doi:10.3390/s130404571. [PDF]
- L. Ferrari, L. Rovati, P. Fabbri and F. Pilati (2013). Disposable Fluorescence Optical pH Sensor for Near Neutral Solutions, Sensors, Vol. 13(1), pp. 484-499; doi:10.3390/s130100484. [PDF]
- S. Cattini, G. Staurenghi, A. Gatti and L. Rovati (2013). In vivo diffuse correlation spectroscopy investigation of the ocular fundus, J. Biomed. Opt., Vol. 18(5), pp. 057001; doi:10.1117/1.JBO.18.5.057001. [PDF]
- Luca Ferrari, Hana Šípová, Ivo Tichý, Karel Chadt, Jiri Homola (2013). Electrochemical surface plasmon resonance biosensor for study of DNA desorption and hybridization, SPIE Proceedings Vol. 8774, Optical Sensors 2013, doi:10.1117/12.2018462
- Palanisamy, N., Riva, C. E., Rovati, L., Cellini, M., Gizzi, C. and Strobbe, E. (2013), Does pupil dilation influence subfoveal choroidal laser Doppler flowmetry?. Acta Ophthalmologica. doi: 10.1111/aos.12130 [PDF]
- P. Fabbri, S. Mohammad Poor, L. Ferrari, L. Rovati, S. Borsacchi, M. Geppi, P.P. Lima and, L.D. Carlos (2013). Highly stable plastic optical fibre amplifiers containing [Eu(btfa)3(MeOH)(bpeta)]: A luminophore able to drive the synthesis of polyisocyanates, Polymer, Vol. 55(2), pp. 488–494, doi: 10.1016/j.polymer.2013.12.043
2012
- S Cattini and L Rovati, A novel method for noninvasive monitoring of ocular fundus status during transpupillary thermotherapy treatment, Sensors Journal, IEEE, Vol. 12 (3), pp. 617-626, 2012 [PDF]
- A. Bosi, L. Bidinelli, D. Saguatti, G.F. Dalla Betta, V. Tyzhnevyi, L. Rovati, G. Verzellesi, G. Batignani, S. Bettarini, F. Forti, F. D’Errico, A. Del Gratta, L. Bosisio, I. Rachevskaia, M. Boscardin, G. Giacomini, M. Calamosca, S. Penzo, F. Cardellini (2012). “Performance of a Radon Sensor Based on a BJT Detector on High-Resistivity Silicon,” IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), p.266-268.
- S. Cattini, L. Rovati (2012). Low-Cost Imaging Photometer and Calibration Method for Road Tunnel Lighting. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, vol. 61, p. 1181-1192 , ISSN: 0018-9456, doi: 10.1109/TIM.2011.2180966 [PDF]
- L. Rovati, P. Fabbri, L. Ferrari, F. Pilati (2012). Plastic Optical Fiber pH Sensor Using a Sol-Gel Sensing Matrix. In: “Fiber Optic Sensors”, p. 415-439, book edited by Moh. Yasin, Sulaiman W. Harun and Hamzah Arof, ISBN 978-953-307-922-6, Published: February 22, 2012 under CC BY 3.0 license M. Yasin, S. W. Harun, H. Arof. Fiber Optic Sensors [PDF]
- L. Ferrari, S. Cattini, L. Rovati, A. Bosi (2012). A simple measuring system for automotive damper wear estimation. In: -. Instrumentation and Measurement Technology Conference . Graz, 13-16 May 2012, p. 539- 543, NY:IEEE, ISBN: 9781457717734 [PDF]
- L. Ferrari, L. Rovati, P. Fabbri, F. Pilati (2012). Photobleaching effects in organic thin film sensing probes. In: -. Instrumentation and Measurement Technology Conference . Graz, 13-16 May 2012, p. 1235-1239 , NY:IEEE, ISBN: 9781457717734
- N. Palanisamy, L. Rovati, Charles E. Riva, M. Cellini, C. Gizzi, E. Strobbe, and E.C. Campos (2012). Does tropicamide affect choroidal blood flow in humans? a laser Doppler flowmetry study. In: Fabrice Manns, Per G. Söderberg, Arthur Ho. Photonics West 2012-BiOS: Biomedical Optics (Special Collection). S. Francisco, 21-26 January 2012, vol. 8209, p. 82091M, NY:SPIE – the international society for optics and photonics, ISBN: 9780819489289
- L. Ferrari, Paola Fabbri, Luigi Rovati, Francesco Pilati (2012). Haematic pH sensor for extracorporeal circulation. In: -. Biosensing and Imaging I. S. Francisco, USA, 22 January 2012, p. 82140E, NY:SPIE – the international society for optics and photonics, ISBN: 9780819488572
- Luigi Rovati, Stefano Cattini, Roberta Salvatori, Antonietta Gatti (2012). Innovative ophthalmic instrument to detect nano- and micro-aggregates in blood circulation. In: Fabrice Manns, Per G. Söderberg, Arthur Ho. Photonics West 2012-BiOS: Biomedical Optics (Special Collection). S. Francisco, January 24-26, vol. 8209, p. 82091N, NY:SPIE – the international society for optics and photonics, ISBN: 9780819489289
- S. Cattini, L. Rovati (2012). Toward the development of a low-cost laser Doppler module for ophthalmic microscopes. In: Fabrice Manns, Per G. Söderberg, Arthur Ho. Photonics West 2012-BiOS: Biomedical Optics (Special Collection). S. Francisco, January 24-26, vol. 8209, p. 82091V, NY:SPIE – The International Society of Optics and Photonics, ISBN: 9780819489289
- L. Rovati, S. Cattini, L. Ferrari (2012). Sistema di misura “low-cost” per il monitoraggio remoto di cadute e la misurazione della postura e del movimento. In: ForItAAL Ambient Assisted Living, III forum italiano, 17-19 Ottobre 2012, PARMA
2011
- L. Rovati, S. Cattini, “Zero-Field Readout Electronics for Planar Fluxgate Sensors Without Compensation Coil,” IEEE Transactions on Industrial Electronics, vol. 59, p. 571-578 , ISSN: 0278-0046, Digital Object Identifier: 10.1109/TIE.2011.2134055, 2011 [PDF]
- L. Rovati, P. Fabbri, L. Ferrari, F. Pilati, “Construction and evaluation of a disposable pH sensor based on a large core plastic optical fiber,” Review of Scientific Instruments, Volume: 82 , Issue: 2 Digital Object Identifier: 10.1063/1.3541795, pp. 023106 – 023106-7, 2011
- L. Rovati, S. Cattini and N. Palanisamy, “Measurement of the fluid-velocity profile using a self-mixing superluminescent diode,” Measurement Science and Technology Volume 22 Number 2, doi: 10.1088/0957-0233/22/2/025402, pp. 025402, 2011 [PDF]
- S. Cattini, L. Rovati, “A novel method for noninvasive monitoring of ocular fundus status during transpupillary thermotherapy treatment,” IEEE Sensors Journal, vol. 12, p. 617 – 626, ISSN : 1530-437X, doi: 10.1109/JSEN.2011.2118197
- A. Pesatori, M. Norgia, L. Rovati, “Self-Mixing Laser Doppler Spectra of Extracorporeal Blood Flow: A Theoretical and Experimental Study,” IEEE Sensors Journal, vol. 12, p. 552-557 , ISSN: 1530-437X, doi: 10.1109/JSEN.2011.2131646
- P. Fabbri, F. Pilati, L. Rovati, R. McKenzie, J. Mijovic, “Poly(ethylene oxide)-silica hybrids entrapping sensitive dyes for biomedical optical pH sensors: Molecular dynamics and optical response,” Optical Materials 33, pp. 1362-1369, 2011
- V. Tyzhnevyi , G. F. Dalla Betta , L. Rovati , G. Verzellesi and N. Zorzi, “BJT detector with FPGA-based read-out for alpha particle monitoring,” Journal of Instrumentation, Vol. 6, doi: 10.1088/1748-0221/6/01/C01051, 2011
- L. Rovati, “Photon correlation spectroscopy in ophthalmology,” Proc. SPIE Advanced Photon Counting Techniques V 8033, pp. 803314, 2011
- M. Norgia, A. Pesatori, L. Rovati, “Optical sensor for extracorporeal blood flow measurement” Proc. IEEE International Workshop on BioPhotonics, Digital Object Identifier: 10.1109/IWBP.2011.5954834, pp 1-3, 2011
- S. Cattini, C. Grana, R. Cucchiara, L. Rovati, “A low-cost system and calibration method for veiling luminance measurement,” Proc. IEEE Instrumentation and Measurement Technology Conference (I2MTC), Digital Object Identifier: 10.1109/IMTC.2011, pp. 1-6, 2011 [PDF]
- M.G. Masi, L. Peretto, R. Tinarelli, L. Rovati, “Assessment of human annoyance under flicker condition,” Proc. IEEE Instrumentation and Measurement Technology Conference (I2MTC), Digital Object Identifier: 10.1109/IMTC.2011.5944241, pp. 1-5, 2011
- N. Palanisamy, L. Rovati, M. Cellini, C. Gizzi, E. Strobbe, E. Campos, C.E. Riva “Effect of timolol on sub-foveal choroidal blood flow using laser Doppler flowmetry,” Proc. SPIE 7885, pp. 78850E, 2011
- S. Cattini, L. Rovati “An optical method for the analysis of the exitance diffused by light-transmitting fiber post,” Proc. SPIE 7884, pp. 78840M, 2011 [PDF]
2010
- Luigi Rovati, Stefano Cattini, “Contactless Two-Axis Inclination Measurement System Using Planar Flux-Gate Sensor”, IEEE Transactions on Instrumentation and Measurement 59(5), pp. 1284 – 1293, 2010 [PDF]
- Michele Norgia, Alessandro Pesatori, Luigi Rovati, “Low-Cost Optical Flowmeter With Analog Front-End Electronics for Blood Extracorporeal Circulators”, IEEE Transactions on Instrumentation and Measurement 59(5), pp. 1233 – 1239, 2010
- Alessandro Chini and Luigi Rovati “Micro-power photovoltaic harvester based on a frequency-to-voltage MPPT tracker”, Electronics Letters 46(8), pp. 587 – 589, 2010
- Michele Norgia, Alessandro Pesatori, Luigi Rovati, “Optical flowmeter sensor for blood circulators”, pp. 97-100 in Sensor and Microsystems, Series: Lecture Notes in Electrical Engineering (LNEE), Springer, 2010 Vol. 54 Malcovati, P.; Baschirotto, A.; D’Amico, A.; Di Natale, C. (Eds.) 2010, ISBN: 978-90-481-3605-6
- L. Rovati, G. Verzellesi, M. Bonaiuti, L. Bidinelli, D. Saguatti, G.-F. Dalla Betta, V. Tyzhnevyi, N. Zorzi, S. Bettarini, “A 2.4-GHz wireless alpha-ray sensor for remote monitoring and spectroscopy”, 2010 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2010, pp. 821 – 824, 2010
- M. Norgia, A. Pesatori, L. Rovati, “Self-mixing laser Doppler: a model for extracorporeal blood flow measurement”, 2010 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2010, p.p. 304 – 307, 2010
- Maria Gabriella Masi, Lorenzo Peretto, Luigi Rovati, and Rafat R. Ansari, “An attempt to understand flicker vertigo: changes in pupil size and choroidal blood flow under flickering conditions,” Proc. SPIE 7550, 75502G, 2010, DOI:10.1117/12.841722
- Nithiyanantham Palanisamy, Ilaria Bruschi, Matteo Bonaiuti, Luigi Rovati, and Charles E. Riva, “Image processing algorithms for ocular fundus reflectometry,” Proc. SPIE 7550, 75501V, 2010, DOI:10.1117/12.841872
- S. Cattini, Michele Norgia, Alessandro Pesatori, and Luigi Rovati, “Blood flow measurement in extracorporeal circulation using self-mixing laser diode,” Proc. SPIE 7572, 75720A (2010), DOI:10.1117/12.840240 [PDF]
2009
- L. Rovati, S. Bettarini, M. Bonaiuti, L. Bosisio, G.-F. Dalla Betta, V. Tyzhnevyi, G. Verzellesi and N. Zorzi, “Alpha-particle detection based on the BJT detector and simple, IC-based readout electronics,” Journal of Instrumentation, Vol. 4(11), p.P11010, 2009
- L. Peretto, C.E. Riva, L. Rovati, G. Salvatori and R. Tinarelli, “Analysis of the effects of flicker on the blood-flow variation in the human eye,” IEEE Transactions on Instrumentation and Measurement, Vol. 58(9), pp. 2916-2922, 2009
- L. Rovati and S. Cattini, “UV-LEDs for monitoring dialysis adequacy,” IEEE Transactions on Instrumentation and Measurement, Vol. 58(5), pp. 1720-1726, 2009 [PDF]
- L. Rovati, S. Cattini, F. Viola, G. Staurenghi, “Measuring dynamics of scattering centers in the ocular fundus during laser heating,” DGaO Proceedings 2009 – ISSN: 1614-8436, 2009 [PDF]
- L. Rovati, P. Fabbri and F. Pilati, “Development of a low-cost pH sensor based on plastic optical fibers,” 2009 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2009, pp. 1662-1666, 2009
- M. Norgia, A. Pesatori and L. Rovati, “Optical flowmeter for blood extracorporeal circulators,” 2009 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2009, pp. 1759-1762, 2009
- L. Rovati and S. Cattini, “Two-axis inclination measurement system based on a planar flux-gate sensor,” 2009 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2009, pp. 1537-1541, 2009 [PDF]
- M.G. Masi, L. Peretto, R. Tinarelli and L. Rovati, “Measurement of the pupil diameter under different light stimula,” 2009 IEEE Intrumentation and Measurement Technology Conference, I2MTC 2009, pp. 1652-1656, 2009
- M. Norgia, A. Pesatori and L. Rovati,, “Optical Flowmeter Sensor for Blood Circulators,” Sensors and Microsystems, AISEM 2009 Proceedings Vol. 54, 2009
2008
- L. Rovati and R. Ansari, “Noninvasive Measurements of Glucose in the Human Body Using Polarimetry and Brewster Reflection off of the Eye Lens” in “Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues,” Valery V. Tuchin Ed., CRC Press, Larry Barksdale (Lincoln, United States), ISBN: 9781584889748, 2008
- S. Cattini and L. Rovati, “A simple readout electronics for automatic power controlled self-mixing laser diode systems,” Rev. Sci. Instrum. 79, 084704, 2008
- L. Rovati, S. Cattini, F. Viola, and G. Staurenghi, “Measuring Dynamics of Scattering Centers in the Ocular Fundus,” International Journal On Smart Sensing and Intelligent Systems, VOL. 1, NO. 3, pp. 799-811, 2008 [PDF]
- G. Verzellesi, G. Batignani, M. Bonaiuti, L. Bosisio, G.-F. Dalla Betta, G. Giacomini, C. Piemonte, L. Rovati, N. Zorzi, M. Baldini, “Application of the BJT Detector for Simple, Low-Cost, and Low-Power Alpha-Particle Detection Systems,” IEEE Nuclear Science Symposium Conference, pp. 780-783, 2007
- L. Rovati and S. Cattini, “On the use of deep UV-LEDs for monitoring dialysis,” IEEE Instrumentation and Measurement Technology Conference Proceedings, pp. 956 – 960, 2008 [PDF]
- L. Rovati, G. Verzellesi, M. Bonaiuti, G. Batignani, L. Bosisio, G.-F D. Betta., G. Giacomini, Piemonte C. and Zorzi N., “Radon alpha-ray detector based on a high-resistivity-silicon BJT and a low-cost readout electronics,” IEEE Instrumentation and Measurement Technology Conference Proceedings, pp. 1403 – 1406, 2008
- M. G. Masi, L. Peretto, R. Tinarelli and L. Rovati, “A Pupil Size Measurement System for the Analysis of the Impact of Flicker on Human Being,” Proc. Of the 16th IMEKO TC-4 Symposium Florence, September, 22-24, pp.419-424, 2008 [PDF]
- M.G. Masi, L.Peretto, R.Tinarelli and L. Rovati, “Modeling of the Physiological Behaviour of Human Vision System Under Flicker Condition,” Proc. Of the 2008 IEEE ICHQP, Wollongong Australia, Semptember 29 – October 1, 2008
- M. Bonaiuti, L. Rovati, and C. E. Riva, “Optic Nerve Reflectance Variations During Neural Activity,” Invest. Ophthalmol. Vis. Sci. 2008 49: E-Abstract 3197, 2008
- C.E. Riva, Bonaiuti M., Rovati L., “Optic nerve reflectance variations in the near-infrared during neural function,” EVER 2008: E-Abstract 5316, 2008
- L. Rovati and S. Cattini, “Diffusing-Wave-Spectroscopy per lo studio del fondo oculare,” Elettroottica: 10° Convegno Nazionale “Strumentazione e metodi di misura elettroottici”, 2008
- M. Bonaiuti and L. Rovati, “Variazioni di riflettanza del disco ottico in presenza di stimolazione visiva diffusa,” Elettroottica: 10° Convegno Nazionale “Strumentazione e metodi di misura elettroottici”, 2008
2007
- L. Rovati, S. Cattini, N. Zambelli, F. Viola, and G. Staurenghi, “In-vivo diffusing-wave-spectroscopy measurements of the ocular fundus,” Optics Express, Vol. 15, Issue 7, pp. 4030-4038, 2007 [PDF]
- L. Rovati, G. Salvatori, L. Bulf, and S. Fonda, “Optical and electrical recording of neural activity evoked by graded contrast visual stimulus,” BioMedical Engineering OnLine 2007, 6:28, doi:10.1186/1475-925X-6-28, 2007 [PDF]
- L. Peretto, L. Rovati, G. Salvatori, R. Tinarelli, and A. E. Emanuel, “A measurement system for the analysis of the response of the human eye to the light flicker,” IEEE Transactions on Instrumentation and Measurement, Vol. 56, No.4, pp. 1384-1390, 2007
- S. Cattini, G. Salvatori, and L. Rovati, “Self-mixing laser velocimeter for retinal blood flow measurements,” SPIE proc. Vol. 6426, 2007
- L. Rovati; N. Zambelli; S. Cattini; F. Viola; and G. Staurenghi, “Optical monitoring of the chorioretinal status during retinal laser thermotherapy,” SPIE proc. Vol. 6426, 2007
- M. Bonaiuti, L. Rovati, and C.E. Riva, “A system for functional imaging of the ocular fundus,” SPIE proc. Vol. 6426, 2007
- L. Peretto, C.E. Riva, L. Rovati, G. Salvatori, and R. Tinarelli, “Experimental evaluation of flicker effects on human subjects,” IEEE Instrumentation and Measurement Technology Conference proceedings, pp. 1-5, 2007
- L. Rovati, S. Cattini, M. Marchesi, and E. Dallago “Closed loop PCB Fluxgate without compensation coil,” IEEE SENSORS Conf. Proc., pp. 852-855, 2007
- F. Viola, N. Zambelli, S. Cattini, D. Galimberti, R. Ratiglia, G. Staurenghi, and L. Rovati, “Measurement of the retina and choroid diffusion coefficients during TTT,” ARVO proc., 105/B214, 2007
- L. Rovati, S. Cattini, F. Viola, and G. Staurenghi, “Motion of the scattering sites in the ocular fundus during transpupillary thermotherapy,” EVER proc., 3255, 2007
- M. Bonaiuti, L. Rovati, and C.E. Riva, “Optic nerve riflectivity variations during diffuse luminance flicker stimulation,” EVER proc., 4452, 2007
- S. Cattini, and L. Rovati, “Elettronica di lettura e compensazione del campo statico per un sensore fluxgate PCB planare,” Atti congresso GMEE 07, pp. 125-126, 2007
- T. Artioli, and L. Rovati, “Sistema optoelettronico per la misura dell’ematocrito del sangue in circolazione Extracorporea,” Atti congresso GMEE 07, pp. 285-286, 2007
- M. Bonaiuti, L. Rovati, and C.E. Riva, “Riflettometria del nervo ottico durante stimolazione visiva,” Atti congresso GMEE 07, pp. 287-288, 2007
- L. Peretto, C.E. Riva, L. Rovati, G. Salvatori, and R. Tinarelli, “Valutazione dell’effetto del flicker sull’occhio umano attraverso la misura di un parametro fisiologico,” Atti congresso GMEE 07, pp. 321-322, 2007
2006
- F. Crespi, M. Donini, A. Bandera, F. Congestri, F. Formenti, V Sonntag, C. Heidbreder, and L. Rovati, “Near-infrared oxymeter biosensor prototype for non-invasive in vivo analysis of rat brain oxygenation: effects of drugs of abuse,” J. Opt. A: Pure Appl. Opt. 8, pp. 528-534, 2006
- G. Salvatori, I.K. Suh, R.R. Ansari, and L. Rovati, “Instrumentation and Calibration Protocol for a Continuous Wave Near Infrared Hemoximeter,” IEEE transactions on instrumentation and measurement, vol. 55, n. 4, pp. 1368-1376, 2006
- M. Bonaiuti, L. Rovati, and C. Riva, “A PC-controlled reflectometer for functional imaging of ocular fundus,” IMEKO Rio De Janeiro, Brazil, 2006 [PDF]
- L. Rovati , N. Zambelli, S. Cattini, and G. Salvatori, “Hollow beam geometry for diffusion temporal light correlation,” IMEKO Rio De Janeiro, p.126, Brazil, 2006 [PDF]
- M. Bonaiuti, C. Riva, and L. Rovati, “Optic nerve blood flow response to flicker can be described by a second order linear system model,” ARVO Invest. Opthalmol. Vis. Sci., Vol. 47, Issue 5, p. 493, 2006
- G. Salvatori, L. Rovati, L. Bulf, and S. Fonda, “Combining near-infrared spectroscopy and electroencephalography to monitor brain function”, Proc. IEEE/IMTC, pp.32-36, 2006 [PDF]
- L. Peretto, L. Rovati, G. Salvatori, and R. Tinarelli, “Investigation on the response of the human eye to the light flicker produced by different lamps,” Proc. IEEE/IMTC, pp.37-42, 2006
- F. Crespi, M. Donini, A. Bandera, F. Congestri, C. Heidbreder, and L. Rovati, “Combined bio-engineering and neurophysiological in vivo technologies allow studying rat brain metabolism and neuronal activities in vivo in real time,” Proc. of SPIE, Vol. 6191, 2006
- S. Cattini, N. Zambelli, and L. Rovati, “Diffusing wave spectroscopy per lo studio dell’emodinamica capillare,” Atti del congresso “ElettroOttica 2006”, pp. 143-146, Frascati (Roma, Italy), June 6-8, 2006
- M. Bonaiuti, L. Rovati, and C.E. Riva, “Flussometria Laser Doppler del nervo ottico durante stimolazione visiva,” Atti del congresso “ElettroOttica 2006”, pp. 131-134,, Frascati (Roma, Italy), June 6-8, 2006
- G. Salvatori, L. Bulf, S. Fonda, and L. Rovati, “Integrazione di strumentazione CW-NIRS e registrazione EEG-PEV per lo studio del sistema sensoriale visivo,” Atti del congresso “ElettroOttica 2006”, pp. 135-138, , Frascati (Roma, Italy), June 6-8, 2006
- L. Rovati, S. Cattini, M. Bonaiuti, and G. Salvatori, “Elettronica di lettura per encoder ottici: un approccio innovativo per migliorare le prestazioni,” Tutto misure, Vol.2, pp.93-94, 2006
- L. Rovati, S. Diavolio, F. Mesini, and A. Bandera, “Sistema ottico per la misura dello spessore di film polimerici per l’industria alimentare,” “Tutto misure,” 2006
- L. Rovati, S. Cattini, N. Zambelli, F. Viola, and G. Staurenghi, “In-vivo diffusing-wave-spectroscopy measurements of the ocular fundus,” “Tutto misure,” 2006
- L. Peretto, L. Rovati, G. Salvatori, and R. Tinarelli, “Risposta dell’occhio umano al flicker luminoso prodotto da diversi tipi di lampade,” Atti del congresso “GMEE 2006”, pp.259-260, 2006
2005
- M. Ruggeri, G. Salvatori, and L. Rovati, “Synchronous phase to voltage converter for true-phase polarimeters,” Measurement Science and Technology Vol. 16, pp. 569-577, 2005
- L. Rovati, M. Bonaiuti, and P. Pavan, “Design of a high-performance optical system for angular position measurement: optical and electronic strategies for uncertainty reduction,” Instrumentation and Measurement, IEEE Transactions Vol. 54, Issue 5, pp. 2075-2081, 2005
- L. Rovati, G. Salvatori, and M. Bonaiuti, “A PC-controlled non-incremental distance meter based on a comb-spectrum combined with a frequency modulated continuous wave interferometer,” Instrumentation and Measurement, IEEE Transactions,Vol. 54, Issue 6, pp. 2486-2492 , 2005
- F. Crespi, A. Bandera, M. Donini, C. Heidbreder, and L. Rovati, “Non-invasive in vivo infrared laser spectroscopy to analyse endogenous oxy-haemoglobin, deoxy-haemoglobin, and blood volume in the rat CNS,” Journal of Neuroscience Methods 145, pp. 11-22, 2005
- M. Ruggeri, G. Salvatori, and L. Rovati, “A true-phase polarimetric system to study bi-anisotropic media,” Proc. IEEE/IMTC, pp. 1039-1043, 2005
- G. Salvatori, I.K. Suh, R.R. Ansari, and L. Rovati, “Instrumentation and calibration protocol for a continuous wave NIRS oxymeter,” Proc. IEEE/IMTC, pp. 1443-1148, 2005
- L. Rovati, and R.R. Ansari, “Optical schemes for polarimetric glucose sensing analyzed by the anatomical eye model of Navarro,” Proc. IEEE/IMTC, pp. 1923-1927, 2005
- L. Rovati, N. Zambelli, and G. Staurenghi, “An optical technique for monitoring chorioretinal temperature during transpupillary thermotherapy,” Proc. SPIE Vol. 5688, pp.201-207, 2005
- G. Staurenghi, and L. Rovati, “Analysis of the temporal fluctuations of the laser light intensity diffused by the chorioretinal tissue during transpupillary thermotherapy (TTT),” Invest. Ophthalmol. Vis. Sci. 2005 46:E-Abstract 2588, 2005
- G. Salvatori, and L. Rovati, “Monitoraggio del sistema nervoso centrale mediante spettroscopia nel vicino infrarosso,” Atti del congresso “GMEE 2005”, pp.277-278, 2005
- L. Rovati, and M. Bonaiuti, “Tecnica di rivelazione zero-crossover per encoder ottici,” Atti del congresso “GMEE 2005”, pp.123-124, 2005
- L. Rovati, S. Davolio, F. Mesini, and A. Bandera, “Sistema ottico per la misura dello spessore di film polimerici per l’industria alimentare,” Atti del congresso “GMEE 2005”, pp.237-238, 2005
2004
- L. Rovati, and F. Docchio, “Autofluorescence methods in ophthalmology,” Journal of Biomedical Optics 09(01), pp. 9-21, 2004
- R.R. Ansari, S. Boeckle, and L. Rovati, “New optical scheme for a polarimetric-based glucose sensor,” Journal of Biomedical Optics 09(01), pp. 103-115, 2004 [PDF]
- L. Rovati, G. Salvatori, “Nonlinear feedback preamplifier for optical trigger circuits,” Electronics Letters 40, Issue 15, pp. 924–926, 2004
- L. Rovati, A. Bandera, M. Donini, G. Salvatori, and L. Pollonini, “Design and performance of a wide bandwidth and sensitive instrument for near-infrared spectroscopic measurements on human tissue,” Rev. Sci. Instrum. Vol. 75, Issue 12, pp. 5315-5325, 2004
- L. Pollonini, R.R. Ansari, and L. Rovati, “Simulation of optical path and volume-under-test calculation in an integrated dynamic light scattering and autofluorescence device,” Proc. SPIE Vol. 5314, pp. 71-78, 2004
- L. Rovati, S. Fonda, L. Bulf, R. Ferrari, G. Biral, G. Salvatori, A. Bandera, and M. Corradini, “Functional cerebral activation detected by an integrated system combining CW-NIR spectroscopy and EEG,” Proc. SPIE Vol. 5326, pp. 118-125, 2004 [PDF]
- F. Crespi, M. Donini, A. Bandera, C. Heidbreder, G. Salvatori, and L. Rovati, “Near-infrared oxymeter prototype for noninvasive analysis of rat brain oxygenation,” Proc. SPIE Vol. 5459, pp. 38-45, 2004
- L. Rovati, L. Pollonini, M. Zanasi, D. Sivieri, and M. Badiali, ”Design of an optical sensor for surface roughness measurements of wood based panels,” Sensors for Industry Conference 04, Proceedings the ISA/IEEE , pp. 55–59, 2004
- L. Pollonini, R.R. Ansari, A. Pasquali, L. Rovati, and L. Quaranta, ”Non invasive evaluation of pigment dispersion syndrome using dynamic light scattering,” Proc. ARVO, Invest. Ophth. & Vis. Sci., pp. 959-B932, 2004
- S. Boeckle, R.R. Ansari, L. Rovati, J.F. King, and K.I. Suh, “Noninvasive monitoring of glucose concentration through the aqueous humor,” Proc. ARVO, Invest. Ophth. & Vis. Sci., p. 4666, 2004
- L. Rovati, L. Pollonini, and R.R. Ansari, “Design and performance of an ophthalmic instrument for dynamic light scattering and fluorescence measurements in ocular tissues,” Proc. IEEE/IMTC, pp. 1975-1979, 2004
- L. Rovati, and G. Salvatori, “Diode zener feedback preamplifier for zero-crossover optical encoders,” Proc. IEEE/IMTC, pp. 2361-2364, 2004
- M. Ruggeri, and L. Rovati, “Polarimetro ad elevate prestazioni per misure di concentrazione di sostanze otticamente attive,” Atti del congresso “ElettroOttica 2004”, pp. 49-52, Pavia (Italy), June 15-17, 2004
- L. Rovati, “Tecniche elettroottiche per migliorare le prestazioni di encoder ottici,” Atti del congresso “ElettroOttica 2004”, pp. 214-217, Pavia (Italy), June 15-17, 2004
- L. Rovati, A. Bandera, and G. Salvatori, “Sistema combinato CW-NIRS ed EEG per la registrazione dell’attività cerebrale da stimoli sensori-motori,” Atti del congresso “ElettroOttica 2004”, pp. 123-126, Pavia (Italy), June 15-17, 2004
- P. Pavan, L. Larcher, E. Caselli, A. Nizzi, L. Rovati, G. Verzellesi, and C. Gerardi, “Threshold voltage drift at R.T. in programmed and erased nanocrystal memory cells,” Proc. 4th Innovative Mass Storage Technology Workshop (IMST), 2004
2003
- L. Pollonini, L. Rovati, A. Pasquali, A. Franzoni, and L. Quaranta, “Pigment dispersion syndrome assessment with a novel dynamic light scattering system,” SPIE proc, Vol. 4951, pp. 161-167, 2003
- S. Böeckle, L. Rovati, and R.R. Ansari, “Glucose sensing using the Brewster-reflection: polarimetric ray-tracing based upon an anatomical eye model,” SPIE proc, Vol. 4965, pp. 116-121, 2003
- R.R. Ansari, and L. Rovati, “Optoelectronics apparatus measures glucose noninvasively: the concentration of glucose is obtained through a combination of interferometry and polarimetry,” Photonics Tech Brief, vol. 27. No.3, page 12, March 2003 (www.nasatech.com)
- L. Rovati, and F. Docchio, “Super-luminescent diodes brighten up inspection,” SPIE OE magazine, p.30, May 2003
- A. Rizzi, D. Marini, L. Rovati, and F. Docchio, “Unsupervised corrections of unknown chromatic dominants using a Brownian-path-based retinex algorithm,” Journal of Electronic Imaging Vol. 12 (3), pp. 431-441, 2003
- L. Rovati, “Design of a High-Performance Optical System for Angular Position Measurement: Optical and Electronic Strategies for Uncertainty Reduction,” Proc. IEEE/IMTC 2003, vol. 2, pp. 1181-1184, 2003
- L. Rovati, A. Bandera, M. Donini, and L. Pollonini, “A novel tissue oxymeter combining the multidistance approach with an accurate spectral analysis,” Proc. IEEE/IMTC 2003, vol. 1, pp. 214-217, 2003
- S. Boeckle, L. Rovati, and R.R. Ansari, “Polarimetric glucose sensing using Brewster reflection applying a rotating retarder analyzer,” SPIE Proc. vol. 5143, pp. 114-125, 2003
2002
- L. Rovati, L. Pollonini, and F. Docchio, “A system for the inspection and quality control of glass slabs,” Rev. Sci. Instrum., Vol. 73(9), pp. 3386-3391, 2002
- S. Boeckle, L. Rovati, and R.R. Ansari, “Polarimetric glucose sensing using the Brewster-reflection off the eye lens: theoretical analysis,” SPIE Proc., Vol. 4624, pp.160-164, 2002 [PDF]
- L. Pollonini, A. Pasquali, L. Rovati, and R.R. Ansari, “Microcontroller-based front-end electronics for simultaneous measurements of dynamic light scattering and natural fluorescence,” SPIE Proc., Vol. 4611, pp.205-212, 2002
- L. Pollonini, L. Rovati, and R.R. Ansari, “Dynamic light scattering and autofluorescence of healthy and pathological ocular tissues,” SPIE BiOS 2002, San Jose, CA (USA), January 19-26, 2002
- L. Pollonini, and L. Rovati, “Strumento laser per misure in-vivo dell’emodinamica e del metabolismo ossidativo dei tessuti,” Atti del congresso “ElettroOttica 2002”, pp. 315-318, Montecatini Terme (Italy), 29-31 Maggio 2002
- L. Pollonini, A. Pasquali, and L. Rovati, “Uno strumento integrato per misure di diffusione dinamica di luce e di autofluorescenza,” Atti del congresso “ElettroOttica 2002”, pp. 407-410, Montecatini Terme (Italy), 29-31 Maggio 2002
- L. Pollonini, and L. Rovati, “Misura dello stato di ossigenazione di muscoli periferici e tessuti cerebrali tramite spettroscopia nel vicino infrarosso,” Atti del XXIX Congresso Nazionale del Gruppo di Coordinamento Misure Elettriche ed Elettroniche (GMEE), pp. 179-180, Parma (Italy), September 9-11, 2002
- L. Quaranta, A. Franzoni, R. Turano, E. Gandolfo , L. Rovati, L. Pollonini, and A. Pasquali, “Particle Sizing of aqueous humor components by Dynamic light scattering in pigmentary glaucoma,” EVER 2002, Alicante (Spain), October 2-5, 2002
2001
- P. Tomassini, L. Rovati, G. Sansoni, and F. Docchio, “Novel optical sensor for the measurement of surface texture,” Rev. Sci. Instrum., Vol. 72(4), pp. 2207-2213, 2001
- L. Rovati, L. Pollonini, and R.R. Ansari, “An integrated instrument for dynamic light scattering and natural fluorescence measurements,” SPIE Proc., Vol. 4245, pp. 192-198, 2001
- R.R. Ansari, L.R. Ansari, and J. Sebag, “Celestial and terrestial tele-ophthalmology: A health monitoring helmet for astronaut/cosmonaut and general public use,” SPIE Proc, Vol. 4245, pp. 177-185, 2001
- S. Pelizzari, L. Rovati, and C. De Angelis, “Rotating polarizer and rotating retarder plate polarimeters: comparison of performances,” SPIE 2001 Testing and Reliability of Optelectronic Devices, SPIE Proc., Vol. 4285, pp. 235-243, 2001
- L. Rovati, “A PC-controlled non-incremental distance meter based on a comb-spectrum combined with a frequency modulated continuous wave interferometer,” IEEE-IMTC Proc., Vol. 2 , pp.1401-1405, 2001
- L. Pollonini, L. Rovati, and R.R. Ansari, “Dynamic light scattering and natural fluorescence measurements of the corneal tissue,” SPIE Proc., Vol. 4434, pp.263-267, 2001
- S. Boeckle, L. Rovati, and R.R. Ansari, “Development of a novel non-invasive sensor for the determination of the blood glucose concentration,” SPIE Proc., Vol. 4434, pp.260-262 , 2001
- L. Rovati, L. Pollonini, and R.R. Ansari, “Integrated instrument for dynamic light scattering and natural fluorescence measurements,” SPIE BiOS 2001, Ophtalmic Technologies XI, Proc. SPIE vol. 4245, pp. 192-198, 2001
- L. Pollonini, L. Rovati, and R.R. Ansari, “Dynamic light scattering and autofluorescence measurements in corneal tissue,” European Conference on Biomedical Optics (ECBO), Munich, German, June 17-21, 2001
- L. Pollonini, S. Boeckle, and L. Rovati, “Diffusione dinamica di luce laser ed autofluorescenza di tessuti oculari,” Atti del XVIII Congresso Nazionale del Gruppo di Coordinamento Misure Elettriche ed Elettroniche (GMEE), pp. 106-107, Siena (Italy), September 18-20, 2001
- L. Rovati, and L. Pollonini, “Un sistema innovativo per la diagnosi di patologie oculari basato sull’integrazione delle tecniche di diffusione dinamica di luce laser ed autofluorescenza,” Bionova 2001 – Idee per la vita, Padova (Italy), November 28 – December 1, 2001
2000
- L. Rovati, and F. Docchio, “Determination of the interferents in blood serum through a novel solid-state colorimeter,” Meas. Sci. Tech., Vol. 11, pp. 185-192, 2000
- L. Rovati, “Optimum preamplification and shaping of signals delivered by photodetectors without internal amplification: a theoretical analysis,” IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing, Vol. 47(5), pp. 399-408, 2000
- P. Tomassini, L. Rovati, and F. Docchio, “A novel optical stylus probe for the measurement of surface roughness and waviness,” EUSPEN 1st Topical Conference on Fabrication and Metrology in Nanotechnology Proc., Vol. 2, pp. 118-126, 2000
- R.R. Ansari, B.S. Singh, L. Rovati, F. Docchio, and J. Sebag, “Monitoring astronaut health through the eye,” NanoSpace 2000 Advancing the Human Frontier Conf., Vol. 1, pp.1-15, 2000
- L. Rovati, and R.R. Ansari, “Dynamic light scattering technique for the monitoring of eye diseases,” SPIE Proc., Vol. 4241, pp. 568-572, 2000
- L. Rovati, and R.R. Ansari, “Diffusione dinamica di luce laser e autofluorescenza dei tessuti oculari: due promettenti tecniche diagnostiche in oftalmologia,” Atti del 6° Convegno Nazionale “Strumentazione e metodi di misura elettroottici”, pp. 133-140, Padova (Italy), 2000 (Relazione invitata)
- L. Rovati, and F. Docchio, “Colorimetro per la misura della concentrazione degli interferenti nel siero sanguigno,” Atti del 6° Convegno Nazionale “Strumentazione e metodi di misura elettroottici” pp. 155-157, Padova (Italy), 2000
- P. Tomassini, R. Rodella, L. Rovati, G. Sansoni, and F. Docchio, “Progetto e realizzazione di un misuratore senza contatto di rugosita’ ed ondulazione di superfici rettificate,” Atti del 6° Convegno Nazionale “Strumentazione e metodi di misura elettroottici” pp. 11-14, Padova (Italy), 2000
1999
- L. Rovati, and F. Docchio, “Low-noise differentiator preamplifier for photogenerated signals,” Rev. Sci. Instrum., Vol. 70 (4), pp. 2169-2170, 1999
- L. Rovati, and F. Docchio, “Low-noise front-end electronics for solid state fluorometers,” Rev. Sci. Instrum., Vol. 70 (9), pp. 3759-3764, 1999
- L. Rovati, and U. Minoni, “High-performance front-end electronics for frequency-modulated continuous-wave interferometers,” IEEE Transaction on Instrumentation and Measurement, Vol. 48 (6), pp. 1191-1196, 1999
- U. Minoni, L. Rovati, M. Bonardi, and F. Docchio, “Dispersive comb-spectrum interferometer: metrological characterization”, IEEE Transaction on Instrumentation and Measurement, Vol. 48 (6), pp. 1197-1200, 1999
- L. Rovati, and F. Docchio, “A novel low-coherence sensor for industrial applications based on a self-mixing super-luminescent diode,” ODIMAP Proc., Vol. II, pp. 87-92, 1999
- F. Docchio, U. Minoni, R. Rodella, and L. Rovati, “Development of an optical sensor for the measurement of surface roughness and waviness,” ODIMAP Proc., Vol. II, pp. 118-123, 1999
- L. Rovati, and F. Docchio, “Signal enhancement and satellite subpeaks degradation in self-mixing super luminescent diode optical tomography,” Proc. CLEO Europe, ATuC3, 1999
- L. Rovati, and F. Docchio, “Design and performance of a low-coherence sensor for industrial applications based on a self-mixing super luminescent diode,” SPIE Proc., Vol. 3823, pp. 164-167, 1999
- F. Docchio, U. Minoni, R. Rodella, L. Rovati, and V. Corallo, “Development of an optical sensor for the measurement of surface roughness and waviness,” SPIE Proc., Vol. 3823, pp. 160-163, 1999
- F. Docchio, and L. Rovati, “Autofluorescence of ocular tissues: a promising diagnostic technique in ophthalmology,” SPIE Proc., Vol. 3749, pp.511-512, 1999
- L. Rovati, and F. Docchio, “Self-mixing superluminescent diode optical tomography,” SPIE Proc., Vol. 3749, pp. 790-791, 1999
1998
- L. Rovati, and F. Docchio, “Low-coherence interferometry using self-mixing super-luminescent diode,” IEEE Photonics technology Letters, Vol. 10 (1), pp. 123-125, 1998
- L. Rovati, U. Minoni, M. Bonardi, and F. Docchio, “Absolute distance measurement using dispersive comb-spectrum interferometry,” Journal of Optics, Vol. 29, pp. 121-127, 1998
- L. Rovati, F. Fankhauser II, F. Docchio, and J. Van Best, “Diabetic retinopathy assessed by dynamic light scattering and corneal autofluorescence,” J. Biomed. Opt., Vol. 3 (3), pp. 357-363, 1998
- U. Minoni, L. Rovati, and F. Docchio, “Absolute distance meter based on a frequency-modulated laser diode,” Rev. Sci. Instrum., Vol. 69 (11), pp. 3992-3995, 1998
- L. Rovati, and F. Docchio, “Characterization of the coherence properties of visible and near infrared laser diode,” Alta Frequenza Vol. 10 (3), pp. 52-54, 1998
- F. Docchio, L. Rovati, J. Van Best, and H. J. van Schaik, “Design and performance of a new fluorometer for corneal autofluorescence measurement,” SPIE Proc., Vol. 3246, pp. 28-34, 1998
- L. Rovati, F. Docchio, C. Azzolini, and J. Van Best, “Corneal autofluorescence in presence of diabetic retinopathy,” SPIE Proc., Vol. 3246, pp. 22-27, 1998
- L. Rovati, and U. Minoni, “Analog signal pre-processing for the performance enhancement of a distance meter based on frequency-modulated continuous-wave interferometry,” IEEE-IMTC Proc., Vol. II, pp. 1141-1144, 1998
- U. Minoni, L. Rovati, M. Bonardi, and F. Docchio, “Metrological characterization of a novel absolute distance meter based on dispersive comb spectrum interferometry,” IEEE-IMTC Proc., Vol. II, pp. 1137-1140, 1998
- L. Rovati, G. Musatti, and F. Docchio, “Self-mixing low-coherence interferometry,” Proc. SPIE, Vol. 3199, pp. 268-272, 1998
- L. Rovati, U. Minoni, M. Bonardi, L. Faustini, and F. Docchio, ” Interferometro a modulazione di frequenza e dispersione cromatica per misure di distanza ad elevata risoluzione,” Atti del 5° Convegno Nazionale “Strumentazione e metodi di misura elettroottici” pp. 28-32, Matera (IT), 1998
- L. Rovati, F. Docchio, C. Azzolini, and J. Van Best, “Autofluorescenza corneale in presenza di retinopatia diabetica,” Atti del 5° Convegno Nazionale “Strumentazione e metodi di misura elettroottici” pp. 214-218, Matera (IT), 1998
- L. Rovati, M. Bonardi, and F. Docchio, “Interferometro a bassa coerenza con retroiniezione di luce,” Atti del 5° Convegno Nazionale “Strumentazione e metodi di misura elettroottici” pp. 381-385, Matera (IT), 1998
1997
- L. Rovati, U. Minoni, and F. Docchio, “Dispersive white light interferometry with a frequency-modulated continuous-wave interferometer for high-resolution absolute measurements of distance,” Optics Letters, Vol. 22 (12), pp. 850-852, 1997
- L. Rovati, “Hollow beam geometry for dynamic light scattering measurements: a theoretical analysis,” Appl. Opt., Vol. 36 (34), pp. 9083-9089, 1997
- L. Rovati, “Theoretical analysis of the hollow beam geometry for dynamic light scattering,” SPIE Proc., Vol. 2971, pp. 14-19, 1997
- F. Docchio, and L. Rovati, “Autofluorescence of ocular tissues: an update of measurements techniques for research and diagnosis,” SPIE Proc., Vol. 2971, pp. 2-7, 1997
- L. Rovati, F. Docchio, F. Fankhauser, and J. Van Best, “Vitreous dynamic light scattering and corneal autofluorescence for early detection of diabetic retinopathy,” IMEKO Proc., Vol. VII, pp. 204-209, 1997
- L. Rovati, and F. Docchio, “Low-coherence tomography using grating interferometry,” IMEKO Proc., Vol. VIII, pp. 1-5, 1997
- L. Rovati, and F. Fankhauser, “In-vivo measurements of Rayleigh ratio of ocular tissue,” Proc. SPIE, Vol. 3192, pp. 196-201, 1997
1996
- L. Rovati, F. Fankhauser II, and J. Ricka, “Design and performance of a new ophthalmic instrument for dynamic light scattering in the human eye,” Rev. Sci. Instrum., Vol. 67 (7), pp. 2615-2620, 1996
- L. Rovati, M. Quaglietti, R. Vesperini, and F. Docchio, “High resolution low coherence interferometry using low cost laser diode,” Proc. CLEO Europe, CPD2. 2 (Post-deadline), 1996
- U. Duerr, F. Fankhauser II, T. Walkow, L. Rovati, and J. Ricka, “In-vivo dynamic light scattering measurements in the cornea of the human eye prior to and after excimer laser refractive surgery,” Invest. Ophth. & Vis. Sci., Vol. 37, p. S568, 1996
- F. Fankhauser II, L. Rovati, and J. Ricka, “In-vivo dynamic light scattering changes of the vitreous in diabetes mellitus,” Invest. Ophth. & Vis. Sci., Vol. 37, p. S973, 1996
- F. Fankhauser II, L. Rovati, and J. Ricka, “In-vivo dynamic light scattering changes of the vitreous in diabetes mellitus,” XX Meeting of the club Jules Gonin, p. 113, 1996
- L. Rovati, F. Fankhauser II, and J. Ricka, “Apparato ad elevate prestazione per misure di diffusione dinamica di luce laser nell’occhio umano,” Atti del 4° Convegno Nazionale “Strumentazione e metodi di misura elettroottici”, 1996
- F. Docchio, L. Rovati, J. van Best, and K. Alkemade, “Fluorimetro corneale semplice, compatto e di basso costo per diagnosi precoci di retinopatia diabetica,” Atti del 4° Convegno Nazionale “Strumentazione e metodi di misura elettroottici”, 1996